Blende | Measurement aperture: 4.5 mm (0.18”) diameter (effective measurement aperture during scanning is depending on the patch size and measurement speed) | |
---|---|---|
Verfügbarer Festplattenspeicher | 2GB | |
Kalibrierung | Manual on external ceramic white reference (included) | |
Kommunikationsschnittstelle | USB 1.1 | |
Konnektivität | Powered USB port | |
Abmessungen (Länge, Breite, Höhe) | i1Pro device: 162 mm x 69 mm x 64 mm (6.4” x 2.7” x 2.5”) | |
Display-Auflösung | 1024x768 pixels or higher | |
Kenntnisstand | Intermediate to Advanced | |
Luftfeuchtigkeit | 30 to 85% RH (non-condensing) | |
Größe des Beleuchtungspunkts | 3 mm (0.12”) | |
Geräteübereinstimmung | 0.3 ∆E00* average, 0.8 ∆E00* max. (deviation from X-Rite manufacturing standard at a temperature of 23ºC (73.4ºF) on 12 BCRA tiles (D50, 2º)) | |
Internetverbindung | Required for software install, download and automatic update | |
Unterstützte Sprachen | Chinese (Simplified), English, French, German, Italian, Japanese, Korean, Portuguese, Spanish | |
Lichtquelle | i1Pro3 Plus LED Illumination (including UV) | |
Macintosh | MacOS X 10.11x, 10.12x, 10.13x, 10.15 (with latest upgrades installed) | |
Messbedingungen | • M0 - UV included - ISO 13655:2017 • M1 - D50 - ISO 13655:2017 • M2 - UV excluded Filter - ISO 13655:2017 |
|
Messfrequenz im Scanmodus | 400 measurements per second | |
Messgeometrie | 45°/0° ring illumination optics, ISO 13655:2017 | |
Media Thickness | 1mm or less | |
Speicher | 2GB Minimum | |
Anzahl der pro Workstation unterstützten Displays | Up to 4 | |
Betriebstemperatur | 10°C to 35°C 50°F to 95°F |
|
Messfeldgröße | Minimal Patch Size in Scanning Mode: 7 x 7 mm (0.28” x 0.28”) (Width x Height) with sensor ruler 10 x 7 mm (0.40” x 0.28”) (Width x Height) without sensor ruler | |
Photometrischer Bereich | 10nm; Sampling interval 3.5nm | |
Prozessor | MAC: Intel® Core 2 Duo CPU or better; WINDOWS: Intel® Core 2 Duo or AMD Athlon™ XP or better | |
Scanlänge | Maximum 260mm (10.24") | |
Unterstützung von Scannertestcharts | Yes | |
Scanfunktionen | Yes | |
Sicherheit | User must have Administrator rights to install and uninstall the application | |
Kurzzeitwiederholgenauigkeit - Weiß | 0.05 dE00 on white (D50,2°, mean of 10 measurements every 3 seconds on white) | |
Scan in einem Durchgang | Yes | |
SDK (Software Development Kit) | Available for OEM customers | |
Software-Modi | Basic & Advanced | |
Spektralanalysesystem | i1® technology with built-in wavelengths check; Holographic diffraction grating with 128-pixel diode array | |
Spektralbereich | 380 - 730 nm | |
Spektralbericht | 380 ... 730 nm in 10 nm steps |
|
Lagerungstemperatur | -20° to 50°C -4° to 122°F |
|
Unterstütztes Profilformat | ICC version 2, version 4.3, & iccMax | |
Gerätefarbe | Black/Silver | |
Benutzererfahrung | Choose between a ‘basic’, wizard-driven interface or an ‘advanced’, user-driven interface for highest level professional results | |
Grafikkarte | MAC: Latest drivers for video card installed; WINDOWS: Latest drivers for video card installed, dual display support requires either 2 video cards or a dual head video card that supports dual video LUTs being loaded |
|
Garantie | Twelve (12) months from the date of sale, unless different local regulations apply. Product registration is required to receive X-Rite technical support during the warranty period. Registration can occur directly through the software, on our website, or via phone. Users are encouraged to register their product within the first 30 days of use. | |
Gewicht | i1Pro device: 285 g (10.1 oz) | |
Lieferumfang | i1Pro 3 Plus spectrophotometer (measurement device), calibration plate, ambient light measurement head, monitor holder, positioning target, scanning ruler, backer board, USB cable. i1Profiler v3.x software for monitor profiling plus QA for monitors and printers. | |
Windows | Windows 7, 8, 8.1, 10 (with latest Service Pack installed) | |
Mehr anzeigen |
Support-Artikel
- DDC and/or ADC Issues With i1Profiler
- Contrast Ratio in i1Profiler
- Connection Issue On PC With Microsoft Security Essentials
- Chromatic Adaptation - What is it...what does it do?
- Smart-Control für Umgebungslicht: Was ist das...was bewirkt das?
- Beheben von Konflikten mit Grafikkarte/VideoLUT oder Farbqualität - MacOS 10.x
- System Level or User Level When Saving Profiles
- Spot Colors Import From Pantone Color Manager
- Software hängt oder stürzt ab während die ersten Farbfelder gemessen werden
- Software "Freeze" While Calibrating Monitor
- Shut Down During Splash Screen - i1Profiler
- Mausklicks blockiert bei Anschluss eines Wacom Tabletts
- Flare Correct™ - Was ist das und wie funktioniert es?
- Display "Quality" Fails With Some Targets and Passes With Others
- Display Quality and Uniformity...What Do They Do?
- Upgrade - i1Basic to new i1Basic Pro?
- Monitor Shows Very Little Change After Calibration
- Installing i1Profiler Software on Windows
- Windows Defender - Turning Off & On
- Why Calibrate Monitor to D65 When Light Booth is D50
- Visual C++ Error When Opening Program
- Using Measure Tool to Read Density and Dot Gain
- Unbefriedigende Ergebnisse mit meinem Drucker-Profil
- Unable to set LUTs Error With i1Profiler
- Unable To Restore Original Profile in i1Profiler
- Brauche ich einen UV-Filter?
- USB 3.0 Technical Information
- Beheben von Konflikten mit Grafikkarten oder VideoLUTs - Win Vista
- Reinstalling a Reluctant i1 Device on Windows PC's
- Monitor Profile Unloading on Windows 7, Windows 8, Windows 10
- License Agreement For i1Profiler 1.6.3 (as of 4/8/2016)
- LUT Tester - Wie finde ich heraus, ob meine Grafikkarte kompatibel ist?
- Fehlermeldung "Instrument nicht gefunden"
- EIZO Displays - Which Models Support ADC?
- Kalibrierung hängt und / oder Patch Lesen ist langsam am PC
- Calibrating and Profiling A Glossy Display
- Ambient Light Measurement Freezes Program
- Upgrade - i1Pro to i1Publish Pro2
- Beheben von Konflikten mit Grafikkarten oder VideoLUTs - Win 7
- X-Rite Device Services Certificate Expiration - Windows 10
- Color Management eLearning Kurs
- Connectivity Issues With USB 3.0
- i1Pro not recognized by i1Profiler on Windows
- Un-installing i1Profiler on Windows
- Upgrade - Can I also upgrade to i1Photo (Pro)