| Blende | Measurement aperture: 4.5 mm (0.18”) diameter (effective measurement aperture during scanning is depending on the patch size and measurement speed) | |
|---|---|---|
| Verfügbarer Festplattenspeicher | 2GB | |
| Kalibrierung | Manual on external ceramic white reference (included) | |
| Kommunikationsschnittstelle | USB 1.1 | |
| Konnektivität | Powered USB port | |
| Abmessungen (Länge, Breite, Höhe) | i1Pro device: 162 mm x 69 mm x 64 mm (6.4” x 2.7” x 2.5”) | |
| Display-Auflösung | 1024x768 pixels or higher | |
| Kenntnisstand | Intermediate to Advanced | |
| Luftfeuchtigkeit | 30 to 85% RH (non-condensing) | |
| Größe des Beleuchtungspunkts | 3 mm (0.12”) | |
| Geräteübereinstimmung | 0.3 ∆E00* average, 0.8 ∆E00* max. (deviation from X-Rite manufacturing standard at a temperature of 23ºC (73.4ºF) on 12 BCRA tiles (D50, 2º)) | |
| Internetverbindung | Required for software install, download and automatic update | |
| Unterstützte Sprachen | Chinese (Simplified), English, French, German, Italian, Japanese, Korean, Portuguese, Spanish | |
| Lichtquelle | i1Pro3 Plus LED Illumination (including UV) | |
| Macintosh | MacOS X 10.11x, 10.12x, 10.13x, 10.15 (with latest upgrades installed) | |
| Messbedingungen | • M0 - UV included - ISO 13655:2017 • M1 - D50 - ISO 13655:2017 • M2 - UV excluded Filter - ISO 13655:2017 |
|
| Messfrequenz im Scanmodus | 400 measurements per second | |
| Messgeometrie | 45°/0° ring illumination optics, ISO 13655:2017 | |
| Media Thickness | 1mm or less | |
| Speicher | 2GB Minimum | |
| Anzahl der pro Workstation unterstützten Displays | Up to 4 | |
| Betriebstemperatur | 10°C to 35°C 50°F to 95°F |
|
| Messfeldgröße | Minimal Patch Size in Scanning Mode: 7 x 7 mm (0.28” x 0.28”) (Width x Height) with sensor ruler 10 x 7 mm (0.40” x 0.28”) (Width x Height) without sensor ruler | |
| Photometrischer Bereich | 10nm; Sampling interval 3.5nm | |
| Prozessor | MAC: Intel® Core 2 Duo CPU or better; WINDOWS: Intel® Core 2 Duo or AMD Athlon™ XP or better | |
| Scanlänge | Maximum 260mm (10.24") | |
| Unterstützung von Scannertestcharts | Yes | |
| Scanfunktionen | Yes | |
| Sicherheit | User must have Administrator rights to install and uninstall the application | |
| Kurzzeitwiederholgenauigkeit - Weiß | 0.05 dE00 on white (D50,2°, mean of 10 measurements every 3 seconds on white) | |
| Scan in einem Durchgang | Yes | |
| SDK (Software Development Kit) | Available for OEM customers | |
| Software-Modi | Basic & Advanced | |
| Spektralanalysesystem | i1® technology with built-in wavelengths check; Holographic diffraction grating with 128-pixel diode array | |
| Spektralbereich | 380 - 730 nm | |
| Spektralbericht | 380 ... 730 nm in 10 nm steps |
|
| Lagerungstemperatur | -20° to 50°C -4° to 122°F |
|
| Unterstütztes Profilformat | ICC version 2, version 4.3, & iccMax | |
| Gerätefarbe | Black/Silver | |
| Benutzererfahrung | Choose between a ‘basic’, wizard-driven interface or an ‘advanced’, user-driven interface for highest level professional results | |
| Grafikkarte | MAC: Latest drivers for video card installed; WINDOWS: Latest drivers for video card installed, dual display support requires either 2 video cards or a dual head video card that supports dual video LUTs being loaded |
|
| Garantie | Twelve (12) months from the date of sale, unless different local regulations apply. Product registration is required to receive X-Rite technical support during the warranty period. Registration can occur directly through the software, on our website, or via phone. Users are encouraged to register their product within the first 30 days of use. | |
| Gewicht | i1Pro device: 285 g (10.1 oz) | |
| Lieferumfang | i1Pro 3 Plus spectrophotometer (measurement device), calibration plate, ambient light measurement head, monitor holder, positioning target, scanning ruler, backer board, USB cable. i1Profiler v3.x software for monitor profiling plus QA for monitors and printers. | |
| Windows | Windows 7, 8, 8.1, 10 (with latest Service Pack installed) | |
| Mehr anzeigen | ||
Support-Artikel
- Failed To Find Any Displays Message During Display Profiling On Windows
- Font Issue On Mac - Text Is Missing Or Corrupt
- Spot Measurements To Get LAB Values With i1Profiler
- Installing i1Profiler Software on Mac
- Installing i1Profiler Software on Windows
- Fehlermeldung "Instrument nicht gefunden"
- Probleme mit der Erkennung von Instrumenten durch Antivirus Soffware
- Interfacing a new i1Pro2 with Older Software
- Known Mac OS X High Sierra 10.13 Issues
- LUT Tester - Wie finde ich heraus, ob meine Grafikkarte kompatibel ist?
- License Agreement For i1Profiler 1.6.3 (as of 4/8/2016)
- Measurement Illumination Conditions
- Minimal Patch Size with i1Pro2
- Monitor Profile Unloading on Windows 7, Windows 8, Windows 10
- Monitor Shows Very Little Change After Calibration
- Profile Reminder - How Often Should I Profile My Display?
- Question Marks on the Measurement and ICC Profile tabs
- Reinstalling a Reluctant i1 Device on Windows PC's
- Beheben von Konflikten mit Grafikkarten oder VideoLUTs - Win 7
- Beheben von Konflikten mit Grafikkarten oder VideoLUTs - Win Vista
- USB 3.0 Technical Information
- Brauche ich einen UV-Filter?
- Unable To Restore Original Profile in i1Profiler
- Unable to set LUTs Error With i1Profiler
- Unbefriedigende Ergebnisse mit meinem Drucker-Profil
- Upgrade - i1Basic to new i1Basic Pro?
- i1Devices and ProfileMaker 5 support
- Ambient Light Measurement Freezes Program
- Automatische Monitorkontrolle (ADC) - Was ist das?
- Calibrating and Profiling A Glossy Display
- Kalibrierung hängt und / oder Patch Lesen ist langsam am PC
- Konflikte mit Grafikkarten oder Video LUTs
- Using Measure Tool to Read Density and Dot Gain
- Visual C++ Error When Opening Program
- What does Diffraction Grating mean?
- White Point Settings
- Why Calibrate Monitor to D65 When Light Booth is D50
- Windows Defender - Turning Off & On
- Verbindungsprobleme des i1Pro 2 bei Verwendung mit dem i1iO oder mit USB-Hub
- i1iO Tables and Exchangeability of i1Pro and i1Pro2
- X-Rite Device Services Certificate Expiration - Windows 10