Color iQC-iMatch v10.7.3.21
Name: Color iQC-iMatch
Version: v10.7.3.21
Previous Version: v10.7.2
Release Date: abril 24, 2023
File Type: PC - Self-extracting Installer
Download File: PC Version
Notes:
Version 10.7.3.21 is a maintenance release that addresses the following issues:
- Can definitions are not being saved.
- Auto base selection is not working in queue.
- Formulas that have been entered using "Alternate Form" cannot be edited or corrected properly.
- Alternate Dry Weight is not working.
- Video preview is not working with iMatch online via RDP for the Ci7x.
- Color iControl crashes with VS3200 using RDP and the preview is unusable.
- Issues creating a waste in the Colorant Editor. Collections over 20 Colorants could not be used.
- Unable to read the setting file (st5) if in use via iControl online.
- Problem formulating using Cans when selecting a different resin.
- Color iControl crashed when there was no default instrument.
- Corrections via iMatch online would sometimes fail if the session was closed and reopened multiple times.
- The M3 condition (and sometimes the M2) would sometimes record an invalid reflectance (1.00) at 670nm.
- There was an issue with manual correction not generating a proper reflectance object.
- Synthesized trials still showed following a correction even if the new System Setting was set to suppress.
Major new and updated features:
- Previously, there was no notification on the license expiration date using SaaS licensing.
- User is now able to create/modify a Two-Constant Paint Collection.
- Enhanced the import/convert process for Collections.
Version 10.7.2.27 is a maintenance release that addresses the following issues:
- Unable to submit data to ColorCert Scorecard Server due to missing XRGA tag
- Color iQC v10.7.0.50 incorrect XRGA tag transfer when in Quick Read mode
- Pass/Fail not indicated properly on the Trend Plot when using “Absolute” option
- QTX export should not change decimal based on local language format
- Memory leak when trying to add Waste to a large collection
- User was not able to see all their Can definitions
- Unable to formulate an Alternate Base if the primary Base/Resin was in the first slot
- If the Resin Sort Order is changed after defining Cans, the Cans were disabled
- Creating a second EFX collection caused iControl to crash
- %Weight / %Volume label in the formula view did not refresh at the right time
- Averaging was different between Cal Mode and regular measure dialog
- Duplicate items were being generated during corrections
- iQC jobs from v8.4 opened in 10.6 showed failing samples
- If a custom toolbar is set while in a language other than English, text was missing from the “File” menu
- eSubmit view would not allow a preceding zero
- CxF import did not consider the wavelength interval
Major new and updated features:
- Formulation warning if using “Auto Full” or “Auto Traditional” when users do not have the selected Can enabled for all resins
- Eliminate zero values when sending corrections through FLINK protocol to a dispenser
- Added an “Edit Formula” button in the QC window
- Updated Datacolor import routine in iMatch for Collections and Standards using XML format
- Automated data import in iQC for XML containing a target Job Template
- Support added for the new X-Rite Ci7530 benchtop
- Support added for the new X-Rite Ci7630 benchtop
- Support added for the new X-Rite Ci7830 benchtop
You may download a copy of these release notes (English) here.