Importing Data from MeasureTool Causes Crash

Measurement data, which have been averaged and saved with MeasureTool 5 (from ProfileMaker 5 Software Suite) cannot be loaded correctly in i1Publish (i1Profiler) software. The measurement data patches are all looking black in the Measurement Preview. When trying to calculate a profile the i1Profiler software crashes.
The averaged measurement text file will be saved with a slightly different data description header than used in the single measurement files. This different information cannot be interpreted correctly by i1Profiler.


Workaround: To solve the isse, the averaged measurement text file can easily be modified by hand. Please follow these steps:
  1. Open one of the original single measurement file using a TEXT Editor
  2. Open the averaged measurement file in the same TEXT Editor
  3. Copy the line 'SampleID SAMPLE_NAME CMYK_C CMYK_M CMYK_Y CMYK_K nm380 ... nm730'
  4. from single measurement file
  5. Replace the line 'SAMPLE_ID SAMPLE_NAME CMYK_C CMYK_M CMYK_Y CMYK_K SPECTRAL_NM_380... SPECTRAL_NM_380'
  6. in the averaged measurement file by the copied line from the single measurement file
  7. Save the modified averaged measurement file. it will now be loaded correctly in i1Publish




Questions? Need a Quote? Contact Us.  1.800.248.9748